Standard
Construction:
All surfaces in contact with water or ice are of stainless steel
or other rust-resistant materialand does not include exterior panels.
Units are factory tested and adjusted
for cylinder ice only and can be manually converted to crushed ice
in the fiels if required. Unit can be set for crushed ice at factory
with no extra charge if specified on order.
Electrical Requirements:
Standard is 208/230V, 3ph, 60Hz. Other configurations are available
on request including 50 Hz.
Dual Ice Selector Switch (Optional):
The selector switch has three settings:
1.) Cylinder (Tube-Ice) only
2.) Crushed Ice only
3.) Both cylinder and crushed ice for split bins.
Tube-Ice Evaporator and Refrigerant
Receiver:
Manufactured in accordance with the A.S.M.E. Code with a 25-year
warranty on domestic installations (see Tube-Ice warranty for details).
R22 is the standard refrigerant.
Remote Control Panel (Optional):
The control panel switch plate can be removed from the machine and
furnished in a remote enclosure if specified at time of order. The
switch box contains on/off, manual harvest/start and stop buttons.
Standard Ice Size:
Tube-Ice approximately 7/8" Diameter x 3/4" Long
(S models)
Tube-Ice approximately 1 1/8" Diameter x 1" long (M models)
Crushed Ice 3/16" to 1/4" thick on all models (approximately
32 lbs./cubic foot)
|